Specification 78987

Performance and Specification Pump LE03 Series:

Pump Model Code Max.Out Press. Actual Ratio Dis. /Cycle Max.Flow Inlet Port Outlet Port
LE03-1S-5 625psi 5.6:1 13.6ml 8.30l/min 1 "FNPT 1/2"FNPT
LE03-1S-7 900psi 7.8:1 9.8ml 6.0l/min 3/4"FNPT 1/2"FNPT
LE03-1S-12 1500psi 14:1 5.9ml 3.83l/min 3/4"FNPT 1/2"FNPT
LE03-1S-21 2600psi 25:1 3.3ml 2.13l/min 3/8"FNPT 1/4 "FNPT
LE03-1S-36 4500psi 41:1 2.0ml 1.28l/min 3/8"FNPT 1/4"FNPT
LE03-1S-71 8800psi 82:1 1.0ml 0.64l/min 3/8"FNPT 1/4 "FNPT
LE03-1S-110 13500psi 126:1 0.6ml 0.42l/min 3/8"FNPT 1/4 "FNPT
LE03-1S-188 15000psi 217:1 0.4ml 0.29l/min 3/8"FNPT 1/4 "FNPT
LE03-1S-220 25000psi 237:1 0.34ml 0.22l/min 3/8"FNPT 1/4 "HF

* HF means female high pressure connection.

Dimensions:

Size A 3.82in.(97mm)
Size B 10in.(254mm)
Size C 1.65in.(42mm)
Size D 4.13in.(105mm)
Size E 4.8in.(122mm)
Size H 5.59in.(142mm)
Size H1 6.89in.(175mm)
Air IN 1/4 Female NPT

Explain:

  • All model code listed are standard.
  • For pumps with handle add “-H” after the model codes.
  • For Pumps with relief valve add“-R” after the model codes.
  • For pumps with Viton seals add “-V” after the model codes.
  • For pumps with Pressure switch valve add “-P” after the model codes.
  • For cold area service add “-C” after the model codes.
  • Other sizes, materials and types are available upon request.

Perfomance Curves:

  • LIQUID FLOW-LTRES/MIN.
  • OUTLET PRESSURE (PSI).